Analysis of hail impact test performance of Hi-MO 5 and oversized module

Ενεργειακά Συστήματα-Φωτοβολταικά

Iris Hellas Logo
Μετάβαση στο περιεχόμενο

Analysis of hail impact test performance of Hi-MO 5 and oversized module

Iris Hellas
Δημοσιεύθηκε από PV Magazine σε Φωτοβολταικά - Διεθνή · Πέμπτη 14 Οκτ 2021
Tags: hailimpactoversizedmodule
A PV module needs to be able to operate in different types of extreme weather conditions and an infinite increase in its size has the potential to bring significant risk to power plants. Hail is a normal global meteorological phenomenon, meaning that analysis of the performance of different size modules in such conditions is increasingly important.
LONGi has conducted new hail performance testing which indicates that, whereas its Hi-MO 5 module (based on a 182mm wafer with dimensions of 2256×1133mm, 2.56m2), is able to withstand testing, the oversized module (dimensions 2384×1303mm, 3.11m2) is unable to do so. A TÜV SÜD report has also demonstrated that Hi-MO 5 was successful in passing a 35mm hail impact test.


1. Technical Feature of PV Glass: The bigger the glass area, the less mechanical strength
The mechanical strength of PV glass is mainly affected by the temperature gradient in the tempered furnace. Because of the significant increase in width (1.3m) of an oversized module, it is more difficult to make the temperature homogenous for glass, meaning that the increase in glass width can result in a reduction in mechanical strength.

2. Analysis of hail impact testing: 100% failure rate of oversized module
In order to verify the technical features of PV tempered glass, several hail tests were conducted in laboratory conditions, with a hail diameter of 35mm and a speed of some 27m/s. 11 points were tested for each module type.
The results indicated that all three oversized modules (3.11m2) failed the test, with a 100% failure rate and with a trend for edge breakage. This supports the view that a significant increase in module size can result in a decrease in mechanical strength, especially at the edge.
In summary, this article analyzes the hail impact test for different size modules and sets out the basic mechanism for testing. It was found that the mechanical strength of an oversized (3.11m2) module will decrease with the increase in glass width, all three modules of this type failing the hail impact test, unlike the 2.56m2 module, which was successful in testing. This may be an important consideration for investors in projects in areas prone to hail conditions, where module reliability assumes particular importance.


Iris Hellas,  Δωδεκανήσου 40, 567 28, Θεσσαλονίκη. Τηλ.:+30 2310 809414  email: [email protected]